DC-AC Current clamp Meter 

AC 1000A Clamp Meter

TES-3040
add to wishlist?
Send Wishlist

Description:


AC 1000A Clamp Meter.

Features:
  • 3-3/4 Digital LCD with bar-graph
  • Auto-power off with Data Hold and MAX/MIN mode
  • Zero Adjustment/Relative Reading
Technical Specifications:

DC Voltage (AC/DC)
RangeDC - 400mV/4V/40V/400V/600V
AC - 4V/40V/400V/600V
AccuracyDC - 0.75% rdg + 2 dgts
AC - 1.5%rdg + 5dgts
Resolution0.1mV(DC); 0.001V (AC)
Input Impedance11M Ω
Overload ProtectionDC 1100V & AC 800V


Current (AC)
Range400/1000A
Accuracy2% rdg + 10 dgts
Resolution0.1A
Overload Protection1100A


Frequency (Hz)
Range100Hz/1KHz/10KHz/100KHz/800KHz
Accuracy0.5% rdg + 5dgts
Resolution0.01Hz
Max Input Sensitivity100mV
Overload Protection>1100A/600Vrms


Ohms (Resistance)
Range400 Ω /4K Ω /40K Ω /400K Ω /4M Ω /40M Ω
Accuracy1% rdg + 5dgts
vAlign=top>Resolution0.1 Ω
Input Impedance600Vrms
Overload Protection0.5VDC


Audible Continuity
Continuity beeperbelow 40 W
Max Open Circuit Voltage0.5V
Overload Protection600Vrms


Diode Test
Resolution0.001V
Accuracy(50Hz-60Hz)1% rdg + 2 dgts
Overload Protection600Vrms
Numerical Display3 3/4 digit liquid crystal display (LCD) maximum reading 3999
Sampling Rate20 times/sec (Bargraph)2 times /sec (Digital Display)
Power Sourceone 006p; 9V or IEC 6F22 or NEDA 1604 Battery
Operating/Storage
/Temperature & Humidity
0 ℃ to 40 ℃ (32 ℉ to 104 ℉ )< 80%RH
-10 ℃ to 60 ℃ (14 ℉ to 140 ℉ )< 70%RH
Dimension239(L) x 66(W) x 34(H)