DC-AC Current clamp Meter 

HVAC Trms Clamp Meter (1000A)

TES-3079
add to wishlist?
Send Wishlist

Description:


HVAC Trms Clamp Meter (1000A)

Features:
  • Check current draw in motors and compressors.
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
Technical Specifications:

AC Current (50Hz to 400Hz): Trms
RangeResolutionAccuracySensitivityOverload Protection
99.99A10mA±2% ±20dgts (50,60Hz)
±4% ±20dgts (40~400Hz)
0.10A1000A
999.99A100mA1.0A


AC Voltage (50Hz to 400Hz) : Trms
RangeResolutionAccuracySensitivityOverload Protection
999.9mV0.1mV±1% ±20dgts (50,60Hz)
±1% ±20dgts (50,60Hz)
2.0mV600V
9.999V1mV±1% ±20dgts (50,60Hz)
±2% ±20dgts (40~400Hz)
0.020V
99.99V10mV0.20V
600.0V100mV2V
Input impedance : 3MΩ

Resistance (Continuity<40Ω on the 999.9Ω range)
RangeResolutionAccuracyOverload Protection
999.9Ω100mΩ1.0% ±10dgts600V
9.999Ω
99.99Ω10Ω
999.9Ω100Ω



RangeResolutionAccuracyOverload Protection
9.999MΩ1KΩ5% ±10dgts600V
99.99MΩ10KΩ


Diode (Continuity<40mV)
RangeResolutionAccuracyOverload Protection
2.000V1mV±2% ±1dgt600V


TRUE Power : (PF>0.7 or θ<45 ° )
RangeResolutionAccuracyOverload Protection
60.00KW (<100A)10W±5%rdg ±20dgts
(50, 60Hz)
600VAC/
1000AAC
600.0KW (>100A)100W


Frequency
RangeResolutionAccuracySensitivity
40Hz / 1KHz0.1Hz±0.5%rdg ±2dgtsACV>0.2V, ACA>6A


μA Trms : (AC+DC) (Burden Voltage : 5mV/μA)
RangeResolutionAccuracySensitivityOverload Protection
99.99μA10nA±1% ±20dgts0.20μA600V
999.9μA100nA2.0μA


DC Voltage
RangeResolutionAccuracySensitivityOverload Protection
999.9mV0.1mV±1.0% ±20dgts
2.0mV600V
9.999V1mV0.020V
99.99V10mV0.20V
600.0V100mV2V
Input impedance : 3MΩ Capacitance

RangeResolutionAccuracyOverload Protection
10.000μF1nF1.5% ±5dgts600V
100.00μF10nF
1000.0μF100nF
7000μF1μF2.5% ±15dgts


Temperature (K-Type thermocouple)
RangeResolutionAccuracyOverload Protection
-50℃ to 900℃0.1℃1% ±1℃30V AC or 60V DC
-58℃ to 1000℉0.1℉1% ±2℉


Phase Angle : (50Hz, 60Hz)
RangeResolutionAccuracySensitivity
50Hz / 60Hz0.1°±3.0°ACV>100V, ACA>10A


Apparent Power
RangeResolutionAccuracyOverload Protection
60.00KVA (<100A)10VA±2.5%rdg ±20dgts600VAC/1000AAC
600.0KVA (>100A)100VA