Flexible AC Current Clamp
Description:
Graphic Power Quality Analyzer
Features:
Technical Specifications:
AC Watt ( 45 ~ 65 Hz, PF 0.5 to 1, CT=1 )
AC Current (45~65 Hz , True RMS)
Harmonics of ACA in % and Magnitude (1 to 50th order)
Power Factor (PF)
Harmonics of AC Voltage in % and Magnitude (1 to 50th order)
Phase Angle ( Φ )
AC Voltage ( 45 ~ 65 Hz, True RMS)
Total Harmonics Distortion (% THD-F , 1 to 50th order)
- Display of Overlapped Voltage and Current Waveform
- Maximum Demand (MD in W,KW,MW) with Programmable Period
- Harmonics Analysis ( V and I ) to the 50th Order
- Display of 25 Harmonics in One Screen with Waveform
- Analysis of Total Harmonics Distortion ( % THD-F )
- Graphic Phasor Diagram
Technical Specifications:
AC Watt ( 45 ~ 65 Hz, PF 0.5 to 1, CT=1 )
| Range | Resolution | Accuracy of Readings |
| 100.0 - 999.9 W | 0.1 W | 2% ± 8 dgts |
| 1.000 - 9.999 KW | 0.001 KW | 2% ± 8 dgts |
| 10.00 - 99.99 KW | 0.01 KW | 2% ± 8 dgts |
| 100.0 - 999.9 KW | 0.1 KW | 2% ± 8 dgts |
| 1000 - 9999KW | 1 KW | 2% ± 8 dgts |
AC Current (45~65 Hz , True RMS)
| Range | Range | Resolution | Accuracy of Readings |
| 30 - 300 A | 0.00 - 300 A | 0.1 A | 1 % of range ± 8 dgts |
| 300 - 999.9 A | 100.0 - 999.9 A | 0.1 A | 1 % of range ± 8 dgts |
| 1000 - 3000 A | 1000 - 3000 A | 1 A | 1 % of range ± 8 dgts |
Harmonics of ACA in % and Magnitude (1 to 50th order)
| Range | Resolution | Accuracy in % | Resolution | Accuracy in Magnitude |
| 10.0 - 300 A | 0.1 % | ±1.0% | 0.1 A | ±1.0% of range ± 0.8A |
| 1000 - 3000 A | 0.1 % | ±1.0% | 1 A | ±1.0% of range ± 3 A |
Power Factor (PF)
| Range | Resolution | Accuracy of Readings |
| 0.00 - 1.00 | 0.01 | ± 1.5 % ± 8 digits |
Harmonics of AC Voltage in % and Magnitude (1 to 50th order)
| Range | Resolution | Accuracy in % | Resolution | Accuracy in Magnitude |
| 50 - 600 V | 0.1 % | ±0.5% | 0.1V | ±0.5 % ± 0.5V |
Phase Angle ( Φ )
| Range | Resolution | Accuracy of Readings |
| -180 ° to 180 ° (0 ° to 360 ° ) | 0.1 ° | ± 1 % ± 2 digits |
AC Voltage ( 45 ~ 65 Hz, True RMS)
| Range | Resolution | Accuracy of Readings |
| 3 V - 600 V | 0.1 V | ± 0.5 % ± 5 dgts |
Total Harmonics Distortion (% THD-F , 1 to 50th order)
| Range | Resolution | Accuracy of Readings |
| 0.0 - 999.9 % | 0.1 % | ± 0.5 % ± 5 digits |
| General Specification | |
| Conductor Size | 150 mm (approx.) |
| Battery Type | 1.5 V SUM-3 *2 |
| Display | 128*64 Dot Matrix |
| Power Consumption | 10 mA (approx.) |
| Auto - Power - Off | 15 minutes |
| LCD update rate | 2 times/sec |
| Dimension | 130mm(L)*80mm(W)*43mm(H), 5.1"(L)*3.1"(W)*1.7"(H) |
| Accessories | Test lead*1 pair, Users manual*1, Batteries 1.5V*2 |
| No. of Sample / Period | 512 ( V & A ), 256 (W) |
| Operating Temperature | -10 ℃ to 50 ℃ |
| Operating Humidity | < 85% RH |
| Storage Temperature | -20 ℃ to 60 ℃ |
| Storage Humidity | < 75 % RH |
| Weight | 450g |