3 Phase Power Analyzer 

Power and Harmonics Analyzer

PROVA-19
add to wishlist?
Send Wishlist

Description:

Power and harmonics analyzer.


Features:
  • True RMS value (V and A)
  • Leakage Current Measurement at 10 μ A Resolution
  • HARMONIC Analysis (V and A) to the 99th Order
  • Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz)
  • Non-interrupted Harmonic Analysis
  • Analysis of Total Harmonic Distortion (THD-F)
  • Analysis of Crest Factor (C.F.)
Technical Specifications:

General Specification
Conductor Size30mm (approx.)
Battery Type1.5V SUM-3 x 2
Display4+2+2 digits LCD
Power Consumption5mA (approx.)
Auto-Power-Off30 minutes
No. Of Samples/Period512 (V & A), 256 (W)
LCD update rate2 times / sec.
Weight200g (battery included)
Operating Temperature-10 ° C to 50° C
Operating Humidity< 85% relative
Storage Temperature-20° C to 60° C
Storage Humidity< 75% relative
Dimension210 (L) x 62 (W) x 35.6mm (H), 8.3" (L) x 2.5" (W) x 1.4" (H)
Accessoriestest leads, Carrying bag x 1, Users manual x 1, Batteries 1.5V x 2
Optionalligator clips


AC Current (50 or 60 Hz, True RMS)
Range(Model 19,21)Range(Model 23)ResolutionAccuracy of Readings
0.30 – 60.00mA0.30 – 60.00mA0.01mA±0.5% ± 5dgts
60.0 – 600.0mA60.0 – 600.0mA0.1mA±0.5% ± 5dgts
0.030 – 3.000 A0.030 – 9.999 A0.001 A±0.5% ± 5dgts
3.00 – 30.00 A10.00 – 60.00 A0.01 A±0.5% ± 5dgts
30.00 – 50.00 A6 0.00 – 99.99 A0.01 A±1.0% ± 5dgts


AC Voltage (50 or 60 Hz, True RMS)

RangeResolutionAccuracy of R.RangeResolutionAccuracy of R.
3V – 250V0.1 V±0.5% ± 5dgts250V – 600V0.1 V±0.5% ± 5dgts


Harmonics of AC Voltage in % and Magnitude (1 to 99th order)
RangeResolutionAccuracy in %ResolutionAccuracy in Magnitude
50V – 600V0.1 %±0.5%0.1 V±0.5% ± 0.5V


Harmonics of ACA in % Percentage and Magnitude (1 to 99th order)

Range(Model 19, 21)Range(Model 23)Res.Accuracy (%)Res.Accuracy of R.
10.00 – 60.00mA10.00 – 60.00mA0.1 %±0.5%0.01mA±0.5% ± 0.1mA
60.0 – 600.0mA60.0 – 600.0mA0.1 %±0.5%0.1mA±0.5% ± 1mA
0.5 – 3.000 A0.5 – 9.999 A0.1 %±0.5%0.001 A±0.5% ± 0.01 A
3.00 – 30.00 A10.00 – 60.00 A0.1 %±0.5%0.01 A±0.5% ± 0.1 A
30.00 – 60.00 A6 0.00 – 99.99 A0.1 %±1.0%0.01 A±1.0% ± 0.1 A


Power Factor and Phase Angle (PF, Φ ,Model 21 and 23)

Range(PF)ResolutionAccuracyRange(Φ)ResolutionAccuracy
0.000 – 1.0000.001± 1°-180° to 180° (0 ° to 360 ° )0.1°± 1°


Total Harmonic Distortion (THD-F, 1 to 99th order) Crest Factor (C.F., Accuracy of Readings)

RangeResolutionAccuracy ofR.RangeResolutionAccuracy ofR.
0.0–999.9%0.1%± 0.5% ± 5 digits1.00 – 99.990.01± 5% ± 30 digits