3 Phase Power Analyzer 

Power Harmonics Analyzer

TES-6830
add to wishlist?
Send Wishlist

Description:

Power harmonics analyzer.


Features:
  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS Value (V 123 and L123)
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)
  • Energy (WH, KWH, KVARH, PFH)
  • Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
  • Display of 35 Parameters in One Screen(3P4W)
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in W, KW, MW) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in One Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples/Period)
  • Analysis of Total Harmonic Distortion (%THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
  • 3 Phase Voltage Unbalance Ratio (VUR)
  • 3 Phase Voltage Unbalance Factor (d0%, d2%)
  • Calculated Unbalance Current through Neutral Line (In)
  • Optical isolated USB Interface
  • Built-in Timer and Calendar for Data Logging
  • Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
  • 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)

Technical Specification:

AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)
RangeResolutionAccuracy of Readings
6800+68018800+68026800+3007
5.0 - 999.9 W0.1 W±1% ± 8dgts±1% ± 8dgts±1% of VA Range ± 8dgts
1.0000 - 999.9 KW0.001 KW±1% ± 8dgts±1% ± 8dgts±1% of VA Range ± 8dgts
10.00 - 99.99 W0.01 KW±1% ± 8dgts±1% ± 8dgts±1% of VA Range ± 8dgts
100.0 - 999.9 KW1 KW±1% ± 8dgts±1% ± 8dgts±1% of VA Range ± 8dgts
1000 - 9999 KW1 KW±1% ± 8dgts±1% ± 8dgts±1% of VA Range ± 8dgts
0.000 - 999.9 MW0.001 MW-±1% ± 8dgts±1% of VA Range ± 8dgts


AC Current (50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1)
RangeResolutionAccuracy of Readings
6800+6801 (Overload Protection AC200A)0.050 - 9.999A0.001A±0.5% ± 5dgts
10.00 - 60.00A0.01A±0.5% ± 5dgts
60.00 - A99.990.01A±1.5% ± 5dgts
6800+6802 (Overload Protection AC2000A)0.04 - 10.00A0.01A-
0.4A - 100.0A0.1A±0.5% ± 5dgts
4.0 - 1000.0A1A±0.5% ± 5dgts
6800+3007 (Overload Protection AC3500A)4 - 300A0.1A±1% ± 5dgts
300.0 - 999.9A0.1A±1% ± 5dgts
1000 - 3000A1A±1% ± 5dgts


AC voltage (50 or 60 Hz, Auto Range, Truw RMS, Crest Factor<4)
RangeResolutionAccuracy of ReadingsRangeResolutionAccuracy of Readings
4.0V - 500.0 (Phase to Neutral)0.1V± 0.5% ± 5dgts4.0 - 600.0V (Phase to phase)0.1V± 0.5% ± 5dgts


Harmonics of AC Voltage in % and in Magnitude
(1 to 99th order, minimum voltage at the 50 or 60 Hz >AC 80V)

RangeIn PercentageIn Magnitude
ResolutionAccuracy of readingResolutionAccuracy of readings
1 - 20 th0.1%± 2%0.1V±2%±0.5V
21 - 49th4% of reading ±2.0%4% of reading ±0.5A
50 - 99 th6% of reading ±2.0%6% of reading ±0.5A


Harmonics of AC current in % and in Magnitude
Model 6800+6801 (100A)
(1 to 99 th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

RangeIn PercentageIn Magnitude
ResolutionAccuracy of readingResolutionAccuracy of readings
1 - 10 th0.1%± 2% of reading ± 1%0.1mA/ 0.1A± 0.2% of reading ± 7dgts
11 - 20th± 2.0% of reading ± 1%± 2% of reading ± 7dgts
21 - 50th (A range)± 5% of reading ± 1%± 5% of reading ± 7 dgts
21 - 50th (mA range)± 10% of reading ± 1%± 10% of reading ± 7 dgts
51 - 50th± 35% of reading ± 1%± 35% of reading ± 7 dgts

Model 6800+6802(1000A);6800+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)
RangeIn PercentageIn Magnitude
ResolutionAccuracy of readingResolutionAccuracy of readings
1 - 20th0.1%± 2%0.1A (6802)/ 0.3A(3007)± 2% of reading ± 0.4A/0.6A
21 - 49th4% of reading ±2.0%± 4% of reading ± 0.4A/0.6A
50 - 99th6% of reading ±2.0%± 6% of reading ± 0.4A/0.6A


Total Harmoic Distortion
RangeResolutionAccuracy (6801)Accuracy (6802)Accuracy (3007)
0.0-20%0.1%± 1%± 2%± 2%
20-100%0.1%± 3% of reading ± 5%± 6% of reading ± 1%± 6% of reading ± 1%
100-999.9%0.1%± 10% of reading ± 10%± 10% of reading ± 1%± 10% of reading ± 1%


Peak Value of Ac Voltage or AC Current, VT=1
RangeSampling TimeAccuracy of reading
50Hz39μS±5% ±30digits
60Hz33μS±5% ±30digits


Crest Factor (C.F.) of ACV or ACA, VT=1
RangeResolutionAccuracy of reading
1.00-99.990.01±5% ±30digits


Frequency in AUTO mode
RangeResolutionAccuracy of reading
45-65 Hz0.01 Hz0.1 Hz


Power Factor (PF)
RangeResolutionAccuracy of reading
0.00-1.000.01±0.04


Phase Angle (Φ)
RangeResolutionAccuracy of reading
-180 to 180 degree0.1 degree±1 degree


General Specification
Conductor Size30mm (approx.)
Conductior Size55mm(approx.), 64 X 24mm(Bus Bar)
Battery Type1.5V SUM-3 x 8
DisplayBot Matrix LCD with backlight
Power consumption140mA (approx.)
External DC InputDC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)
LCD update rate1 times/sec
No. of samples/period1024
Operating Humidity<85% relative
Operating temperature-10°C to 50°C
Storage Humidity<75% relative
Weight1160g
Dimension (6800)257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H)
Dimension (6801)210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)
Dimension (6802)244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H)