DC-AC Current clamp Meter
Description:
AC/DC True RMS WATT CLAMP.
Features:
DC Current (Autorange & Manual)
ANALOG OUTPUT (Autorange & Manual )
AC Current (Autorange & Manual, True RMS)
ANALOG OUTPUT (Autorange & Manual)
DC Voltage (Autorange & Manual, Overload Protection 800VAC for all Range)
AC Voltage (Autorange & Manual ,True RMS, Input Impedance 5M W for all Range )
Audible Continuity
TEMP K TYPE ℃ (Autorange & Manual)
AC+DC 250V POWER (Autorange & Manual)
AC+DC 600V POWER (Autorange & Manual)
- AC+DC 1200KW
- DC/AC 2000A & ANALOG OUTPUT
- Cable F 55mm
- True RMS
- Temperature ( ℃ or ℉ )
- 0.1 ℃ / ℉ Resolution '
DC Current (Autorange & Manual)
| Range | Resolution | Accuracy | Overload Protection |
| 400A | 0.1A | +/-1.5%+/-3dgts | 3000A |
| 2500A | 1A | +/-1.5%+/-3dgts | 3000A |
ANALOG OUTPUT (Autorange & Manual )
| Range | OUTPUT | Accuracy | Overload Protection |
| 400A | 1mV/A | +/-2.5%+/-0.5A | 600V AC |
| 2500A | 1mV/A | +/-2.5%+/-5A | 600V AC |
AC Current (Autorange & Manual, True RMS)
| Range | Resolution | Accuracy | Overload Protection | |
| 50/60Hz | 40-400Hz | 3000A | ||
| 400A | 0.1A | +/-1.5%+/-5dgts | +/-2.0%+/-5dgts | 3000A |
| 2100A(0-1000) | 1A | +/-2.0%+/-5dgts | +/-2.5%+/-5dgts | 3000A |
| 2100A(1000-2100) | 1A | +/-2.5%+/-5dgts | +/-3.0%+/-5dgts | 3000A |
ANALOG OUTPUT (Autorange & Manual)
| Range | OUTPUT | Accuracy | Overload Protection |
| 400A | 1mV/A | +/-2.5%+/-0.5A | 600V AC |
| 2100A | 1mV/A | +/-2.5%+/-5A | 600V AC |
DC Voltage (Autorange & Manual, Overload Protection 800VAC for all Range)
| Range | Resolution | Accuracy | Input Impedance |
| 400mV | 0.1mV | +/-1.5%+/-3dgts | 10MΩ |
| 4V | 0.001V | +/-1.5%+/-3dgts | 5M Ω |
| 40V | 0.01V | +/-1.5%+/-3dgts | 5MΩ |
| 400V | 0.1V | +/-1.5%+/-3dgts | 5M Ω |
| 600V | 1V | +/-1.5%+/-3dgts | 5M Ω |
AC Voltage (Autorange & Manual ,True RMS, Input Impedance 5M W for all Range )
| Range | Resolution | Accuracy | Overload Protection |
| 4V | 0.001V | +/-1.5%+/-5dgts | 800VAC |
| 40V | 0.01V | +/-1.5%+/-5dgts | 800VAC |
| 400V | 0.1V | +/-1.5%+/-5dgts | 800VAC |
| 600V | 1V | +/-1.5%+/-5dgts | 800VAC |
Audible Continuity
| Range | Continuity Beeper | Open Circuit Voltage | Overload Protection |
| 400 W | <=40 W (approx) | <=0.5V | 600VAC |
TEMP K TYPE ℃ (Autorange & Manual)
| Range | Resolution | Accuracy | Overload Protection |
| -40~0 ℃ | 0.1 ℃ | +/-2.0%+2 ℃ | 600VAC |
| -0~400 ℃ | 0.1 ℃ | +/-0.5%+1 ℃ | 600VAC |
| 400 ~1000 ℃ | 1 ℃ | +/-0.8%+1 ℃ | 600VAC |
AC+DC 250V POWER (Autorange & Manual)
| Range | Resolution | Accuracy | Overload Protection |
| 40KW | 0.01KW | +/-2.5%+/-5dgts | 800VAC 3000A |
| 400KW | 0.1KW | +/-2.5%+/-5dgts | 800VAC 3000A |
AC+DC 600V POWER (Autorange & Manual)
| Range | Resolution | Accuracy | Overload Protection |
| 400KW | 0.1KW | +/-2.5%+/-5dgts | 800VAC 3000A |
| 1200KW | 1KW | +/-2.5%+/-5dgts | 800VAC 3000A |
| General Specification | |
| Jaw Opening | Cable F 55mm Bus Bar 65mm(D) x 24mm(W) |
| Power Source | One 006P 9V or IEC 6F22or NEDA 1604 Battery |
| Operating Temperature | 0 ℃ ~ 40 ℃ ( 32 ℉ ~104 ℉ ) |
| Operating Humidity | Less than 80% RH |
| Dimensions | 10.7"(L) x 4.4"(W) x 18"(H) 271mm(L) x 112mm(W) x 26.2mm(H) |
| Weight | 647g / 22.8oz. (Battery included) |