萬用表 

Digital Multi-Meter

PROVA-801
添加到願望清單?
發送願望清單

Description:

Digital multi meter.


Features:
  • 60,000 count and dual input channels
  • >0.04% DC basic accuracy and 0.2% AC basic accuracy
  • Bandwidth of 10KHz(max)
  • Fast ACV, ACA response
  • Dual channels measurement similar to a dual channels DSO( V+V , V+A)
Technical Specifications:

The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.

Continuity : (, open voltage 3V approx.)
RangeResolutionBeeperOverload Protection
999.99 Ω0.01 Ω< 40 Ω ( approx )AC 1000V


Frequency : (TTL)(Overload Protection AC 1000V)
Range ( Auto )ResolutionAccuracy
1.000Hz -2MHz0.0001Hz - 0.0001MHz±0.005%±4dgts


DC Voltage: (Input Impedance: 10MΩ )(Overload Protection DC 1000V)
RangeResolutionAccuracy
60.000mV0.001mV±0.2%±9dgts
600.00mV0.01mV±0.04%±6dgts
6.0000V0.0001V±0.04%±6dgts
60.000V0.001V±0.04%±6dgts
600.00V0.01V±0.04%±6dgts
1000.0V0.1V±0.08%±6dgts


DC Current: (10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )
RangeResolutionAccuracy
600.00 μ A0.01 μ A±0.4%±20dgts
6000.0 μ A0.1 μ A±0.2%±20dgts
60.000mA0.001mA±0.4%±20dgts
600.00mA0.01mA±0.2%±20dgts
1.0000A0.0001A±0.2%±20dgts
10.000A 10.001A±0.6%±20dgts


Diode Test : (open voltage 3V approx. overload protection AC 1000V)
RangeResolutionAccuracyShort Circuit Current
3.0000V0.0001V±2%±5dgts0.8 mA typical


Duty Cycle : (%, TTL, 1Hz – 600KHz) (Overlo ad Protection AC 1000V)
RangeResolutionAccuracy
0.001% - 9.999%0.001%±30d/KHz±30dgts
10.00% - 100.00%0.01%±3d/KHz±3dgts


Resistance: ( Ω )
RangeResolutionAccuracyOverload Protection
999.99 Ω0.01 Ω±0.25%±9dgtsAC 1000V
9.9999K Ω0.0001K Ω±0.15%±6dgtsAC 1000V
99.999K Ω0.001K Ω±0.15%±6dgtsAC 1000V
999.99K Ω0.01K Ω±0.15%±6dgtsAC 1000V
9.9999M Ω0.0001M Ω±0.3%±9dgtsAC 1000V
40.000M Ω0.001M Ω±1.5%±9dgtsAC 1000V


Capacitance: (, auto range , and for film capacitor or better)
RangeResolutionAccuracy 1
60.00nF0.01nF±1.2%±8dgts
600.0nF0.1n F±2.5%±8dgts
6.000 μ F0.001 μ F±2.5 %±8dgts
60.00 μ F0.01 μ F±3.0%±8dgts
600.0 μ F0.1 μ F±5.0%±8dgts


AC Voltage: The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz-10KHz, average sensing. Input Impedance is 10M Ω , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the un it.
Range (ACV)ResolutionAccuracy (50/60Hz)Accuracy (45Hz - 1KHz)Accuracy (20Hz - 45Hz)Accuracy (1KHz-10KHz)
60.000mV0.001mV±0.2%±40dgts±0.6%±40dgts±1.6%±50dgts±4%±40dgts
600.00mV0.001mV±0.2%±40dgts±0.6%±40dgts±1.6%±50dgts±2%±40dgts
6.0000V0.01mV±0.2%±40dgts±0.6%±40dgts±1.6%±50dgts±2%±40dgts
60.000V0.0001V±0.2%±40dgts±0.6±40dgts±1.6%±50dgts±2%±40dgts
600.00V (0-400V)0.001V±0.2%±40dgts±1.0%±40dgts±1.6%±50dgts±9%±40dgts
600.00V (400-600V)0.01V±0.2%±40dgts±1.0%±40dgts±1.6%±50dgtsNot Specified
1000.0V (0-400V)0.1V±0.2%±40dgts±4%±60dgts±1.6%±50dgts±4%±80dgts
1000.0V (400-1000V)0.1V±0.2%±40dgts(45Hz - 400Hz) ±4%±60dgts±1.6%±50dgtsNot Specified


Supplemental Dual Channels Specification (DC – 400Hz):The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
/ACV (Ch2)DCV (Ch2)ACA (Ch2)DCA (Ch2)
ACV (Ch1)±2%±( V1 - V2 )* 200 PPM (Ch1, Ch2)±0.9%±(V1 - V2) * 20PPM (Ch1, Ch2)±0. 2 μ A / V( μ A,Ch2)
± 2 μ A / V (mA,Ch2)
±0.4mA / V (A, Ch2)
±4mV / A (mV, Ch1)
± 9mV / A (V, Ch1)
±0.5% (Ch1, Ch2)
DCV (Ch1)±0.9%±(V1 - V2) * 20 PPM (Ch1, Ch2)±0.5% (Ch1,Ch2±0.5% (Ch1, Ch2)±0.5% (Ch1, Ch2)


AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz – 10KHz,average sensing, , 10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse.If the AC reading is less than 100 least significant digits, it is set to zero by the unit )
Range (ACA)ResolutionAccuracy (50/60Hz)Accuracy (45Hz - 1KHz)Accuracy (20Hz - 45Hz)Accuracy (1KHz -10KHz)
600.00 μ A0.01m A±0.6%±40dgts±0.8%±40dgts±2%±20dgts±4%±20dgts
6000.0 μ A0.1m A±0.6%±40dgts±0.8%±40dgts±2%±20dgts±4%±20dgts
60.000mA0.001mA±0.6%±40dgts±0.8%±40dgts±2%±20dgts±0.9%±20dgts
600.00mA0.01mA±0.6%±40dgts±0.8%±40dgts±2%±20dgts±0.9%±20dgts
1.0000A0.0001A±0.6%±40dgts±0.8%±40dgts±2%±20dgts±2.5%20dgts
10.000A 10.001A±0.9%±40dgts±0.9%±40dgts±3.9%±20dgts±2.5%20dgts


Range (ACA)Accuracy (20Hz - 45Hz)Accuracy (1KHz – 10KHz)Accuracy (10KHz – 20KHz)
600.00 μ A±1%±20dgts±2%±20dgts±1%±20dgts
6000.0 μ A±1%±20dgts±2%±20dgts±1%±20dgts
60.000mA±1%±20dgts±0.5%±20dgts±1%±20dgts
600.00mA±1%±20dgts±0.5%±20dgts±1%±20dgts
1.0000A±1%±20dgts±1.5%±20dgtsNot Specified
10.000A 1±2%±20dgts±1.5%±20dgtsNot Specified


General Specification
Battery Type:9V
Display:5 + 5 digits LCD with 30 segments bar graph
Range Selection:auto and manual
Overload Indication:OL
Power Consumption:4 mA ( approx )
Low battery Indication:
Operating Temperature:-10 ℃ to 50 ℃
Operating Humidity:
less than 85% relative

Altitude:up to 2000M
Storage Temperature:-20 ℃ t o 60 ℃
Storage Humidity:less than 75% relative
Dimension:207mm(L) x 101mm (W) x 47mm (H)8.15" (L) x 4" (W) x 1.85" (H)
Weight:430g / 15.2oz (battery included)
Accessories:
Users manual x 1
9V battery x 1
801A1:Holster
801A2:RS-232C inface cable+software